Sale!

Kidde-Fenwal05-296623-753Heatilator Ignition Control Board Module Replacement

Original price was: $301.11.Current price is: $60.22.

SKU: 4395503055 Categories: , ,

Description

Fenwal 05-296623-753 24VAC, Ignition Time 6.8 Seconds. Heatilator
Direct Spark CSA ignition control module.This control is no longer available.A Fenwal direct replacement will be supplied.

Technical Specification

SPECIFICATIONS

Size With Enclosure:5.69 x 3.94 x 1.87 in(144.4 x 99.9 x 47.5 mm) Without Enclosure: 5.50 x 3.75 x 2.00 in(139.7 x 95.3 x 50.8 mm)
Weight (with enclosure) Approximately 7.0 oz (200 g)
Input Voltage 24 VAC %/-15%, 50/60 Hz
Input Current Drain 90 mA RMS maximum (270 mA peak) while sparking. Does not include valve power.
Valve Relay Contact Rating 1.0 A (Inrush 2.5 A maximum)
Combustion Blower Relay 8A @ 250 VAC (1/4 HP)
Prepurge None, 15 or 30 seconds depending on model. Without prepurge there is less than 1.0 second delay before single try for ignition.
Ambient Temperature Limits -40 def. F and 힞 deg. F ( -40 anddeg. C)
Moisture Resistance Each module is conformal coated to operate to 90% R.H. However, care must be taken to protect module from direct exposure to water.
Tries for Ignition Available in one- or three-try versions.
Trial-for-Ignition Periods 3.3, 4.7, 6.8, 10.0, or 12.0 seconds, depending on model.
Flame Failure Retry When loss of flame occurs after the initial try for ignition. the control system provides one retry on single-try models and two retries on three-try models
Flame Current 5 microamp minimum
Flame Failure Response Time Within 0.8 second
Spark Rate 60 sparks per second (synchronous)
Types of Gas Natural. LP, or manufactured
Connections 1/4 inch spade type (3/16 inch for V1)
Sensor Single spark and sense using high voltage spark electrode as the sensing element or remote sensing using a separate sensing element.
Enclosure (Optional) Gray Noryl fire retardant plastic

CONTROL CONFIGURATION

Method of Flame Sensing

Single Spark and Sense

Tries for Ignition

Single Try for Ignition

Mounting/Enclosure Configuration

Fire Retardant Plastic Enclosure

Prepurge Period

No Prepurge

Blower Relay

No Relay

Trial-For-Ignition (TFI) Time

6.8 Seconds