Description
CG Air Touchstone Spa Control No Heater CAST-201-01-01-04A
The CAST-201 unit is a stand-alone Air Switch Timer that provides for a simple user interface. The controller can be field configured to one of four software program options. This NEMA plug-in module has On, Off and Timer functions; allowing a Pump or a Blower to operate for up to 20 minutes before shutting itself down. All operated by an Air Button interface for ease of use.
Model that ends in XXA – this is a multiple speed setting.
The first press of the air button will start the Blower at high speed. This will also start a 20-minute countdown timer which will automatically turn off the Blower when time expires. If more time is desired after the Blower turns off automatically, press the air button again to start a new 20-minute session.
The second press of the air button will change the speed of the Blower to medium speed.
The third press of the air button will change the speed of the Blower to low speed.
The fourth press of the air button will cause the Blower to change speeds from low to high in an oscillating manner (“Massage Mode”).
The fifth press of the air button will turn the blower off.
20 minutes after the Blower has been turned off (either manually or automatically) the Blower will turn on again automatically for one minute. This cycle will purge out any residual moisture that is in the air system making the system fresh and ready for
the next bath.
Model that ends in XXB (not this model)
The first press of the air button will start the Blower at high speed. This will also start a 20-minute countdown timer which will automatically turn off the Blower when time expires. If more time is desired after the Blower turns off automatically, press the air button again to start a new 20-minute session.
The second press of the air button will turn the Blower off manually.
20 minutes after the Blower has been turned off (either manually or automatically) the Blower will turn on again automatically for one minute. This cycle will purge out any residual moisture that is in the air system making the system fresh and ready for the next bath.